top of page
Writer's pictureTeam Adsentec

Thermo Fisher Scientific Inc.

Updated: Aug 13, 2022

Location: Waltham, MA, USA

 

Products:


Ambient Gas Monitoring (i and iQ Series of Gas Analyzers)


42I NO-NO2-NOx Analyzer #chemiluminescence (range: 0–0.05 to 100 ppm, 0–0.1 to 30 mg/m3; LoD: 0.4 ppb)

42IHL High Level NO-NO2-NOx Analyzer #chemiluminescence (range: 0–10 to 5000 ppm; LoD: 50 ppb)

42ID NOx only Analyzer #chemiluminescence (range: 0–0.05 to 20 ppm, 0–0.1 to 150 mg/m3; LoD: 0.4 ppb)

42ITL Trace Level NOx only Analyzer #chemiluminescence (range: 0–5 to 1000 ppb, 0–10 to 2000 ug/m3; LoD: 50 ppt)

42ILS Low Source NO-NO2-NOx Analyzer single-channel #chemiluminescence (range: 0–0.5 to 500 ppm, 0–2 to 750 mg/m3; LoD: 0.4 ppb)


42IQ NO-NO2-NOx Analyzer #chemiluminescence (range: 0–20 ppm, 0–30 mg/m3; extended range: 0–100 ppm, 0–150 mg/m3; LoD: 0.4 ppb)

42IQTL Trace Level NO-NO2-NOx Analyzer #chemiluminescence (range: 0–1000 ppb, 0–1500 ug/m3; LoD: 50 ppt)

42IQHL High Level NO-NO2-NOx Analyzer #chemiluminescence (range: 0–5000 ppm, 0–7500 mg/m3; LoD: 0.05 ppm)

42IQLS NO-NO2-NOx Analyzer #chemiluminescence (range: 0–100 ppm, 0–150 mg/m3; extended range: 0–500 ppm, 0–750 mg/m3; LoD: 0.01 ppm)

42IQD NOx only Analyzer #chemiluminescence (range: 0–20 ppm, 0–30 mg/m3; extended range: 0–100 ppm, 0–150 mg/m3; LoD: 0.4 ppb)

42IQD NOy only Analyzer single chamber #chemiluminescence (range: 0–5 to 1000 ppb, 0–10 to 2000 ug/m3; LoD: 50 ppt) measures most oxides of nitrogen with the exception of NH3 and N2O



43I Sulfur Dioxide Analyzer pulsed #fluorescence (range: 0–0.05 to 10 ppm, 0–0.2 to 25 mg/m3; LoD: 0.5 ppb)

43IHL High Level Sulfur Dioxide Analyzer pulsed #fluorescence (range: 0–10 to 1000 ppm, 0–20 to 2000 mg/m3; extended range: 0–100 to 10,000 ppm, 0–2000 to 20,000 mg/m3; LoD: 0.5 ppm)

43ITLE Trace Level Enhanced Sulfur Dioxide Analyzer pulsed #fluorescence (range: 0–10 to 1000 ppb, 0–20 to 2000 ug/m3; LoD: 0.05 ppb)


43IQ Sulfur Dioxide Analyzer pulsed #fluorescence (range: 0–10 ppm, 0–25 mg/m3; extended range: 0–100 ppm, 0–250 mg/m3; LoD: 0.25–1 ppb)

43IQTL Trace Level Sulfur Dioxide Analyzer pulsed #fluorescence (range: 0–1000 ppb, 0–2000 ug/m3; LoD: 0.05–0.28 ppb)

43IQHL High Level Sulfur Dioxide Analyzer pulsed #fluorescence (range: 0–1000 ppm, 0–3000 mg/m3; LoD: 0.5–2 ppm)



48I Carbon Monoxide Analyzer utilizes gas filter correlation technology #NDIR (range: 0–1 to 10,000 ppm, 0–1 to 10,000 mg/m3; LoD: 0.04 ppm)

48ITLE Trace Level Enhances Carbon Monoxide Analyzer utilizes gas filter correlation technology #NDIR (range: 0–1 to 1000 ppm, 0–1 to 1000 mg/m3; LoD: 0.04 ppm)

EPA Designated method #RFCA-0981-054

48IHL High Level Carbon Monoxide Analyzer utilizes gas filter correlation technology #NDIR (range: 0–50 to 20,000 ppm, 0–50 to 20,000 mg/m3; LoD: 4 ppm)


48IQ Carbon Monoxide Analyzer utilizes gas filter correlation technology #NDIR (range: 0–10,000 ppm, 0–10,000 mg/m3; LoD: 0.04 ppm)

48IQTL Trace Level Carbon Monoxide Analyzer utilizes gas filter correlation technology #NDIR (range: 0–1000 ppm, 0–1000 mg/m3; LoD: 0.02 ppm)



49I Ozone dual-cell #UV photometric (range: 0–0.05 to 200 ppm, 0–0.1 to 400 mg/m3; LoD: 0.5 ppb)

49IPS Ozone Primary Standard dual-cell #UV photometric (range: 0–0.05 to 10 ppm, 0–0.2 to 25 mg/m3; LoD: 0.5 ppb)


49IQ Ozone Analyzer dual-cell #UV photometric (range: 0–200 ppm, 0–400 mg/m3; LoD: 0.5 ppb)

49IQPS Ozone Primary Standard #UV photometric (range: 50–5000 ppb, 100–10,000 ug/m3; LoD: 0.5 ppb)



450I Hydrogen Sulfide and Sulfur Dioxide Analyzer pulsed #fluorescence (range: 0–0.05 to 10 ppm, 0–0.2 to 25 mg/m3; extended range: 0–0.5 to 100 ppm, 0–2 to 250 mg/m3; LoD: 0.5–6 ppb)


450IQ Hydrogen Sulfide and Sulfur Dioxide Analyzer pulsed #fluorescence (range: 0–10 ppm, 0–25 mg/m3; extended range: 0–100 ppm, 0–250 mg/m3; LoD: 0.25–1 ppb) operates on the principle that H2S can be converted to SO2



17I Ammonia Analyzer #chemiluminescence (range: 0–0.05 to 20 ppm, 0–0.1 to 30 mg/m3; extended range: 0–0.2 to 100 ppm, 0–0.5 to 150 mg/m3; LoD: 1 ppb)

has 3 modes of operation: NO, NOx, Nt (NO + NO2 + NH3) all based on NO conversion/measurement



55I Direct Methane & Non-Methane Hydrocarbon Analyzer uses back-flush #GC #FID (range: 0–5 to 1000 ppm; extended range: 0–20 to 5000 ppm, 0–0.5 to 150 mg/m3; LoD: 0.05 ppm CH4 or NMHC as propane



51I, 51ILT and 51IHT Total Hydrocarbon Analyzer #FID (range: 0–1 to 10,000 ppmc; LoD: 0.05 ppmc)

Available in both high-temperature and low-temperature versions



410I Carbon Dioxide Analyzer #NDIR (High Level range: 0–0.5 to 25%; Standard range: 0–200 to 10,000 ppm; High Level LoD: 20 ppm, Standard LoD: 0.2 ppm)

Also Available with an Oxygen Sensor Module using #paramagnetic sensing technology


410IQ Carbon Dioxide Analyzer #NDIR (range: 0–10,000 ppm; LoD: 1 ppm)

410IQHL High LevelCarbon Dioxide Analyzer #NDIR (range: 0–250,000 ppm or 25%; LoD: 40 ppm)






46I Nitrous Oxide Analyzer utilizes gas filter correlation technology #NDIR (range: 0–0.2 to 50 ppm, 0–0.1 to 30 mg/m3; LoD: 0.02 ppm)

46IHL High Level Nitrous Oxide Analyzer utilizes gas filter correlation technology #NDIR (range: 0–10 to 2000 ppm, 0–20 to 4000 mg/m3; LoD: 0.3 ppm)


15I Hydrogen Chloride Analyzer #NDIR (range: 0–5 to 5000 ppm, 0–10 to 7500 mg/m3; LoD: 0.2 ppm)




60I Multi-Gas Analyzer #NDIR (for CO 0–2500/0.5 ppm, CO2 0–25/0.05 %, NO 0–2000/0.5 ppm, NO2 0–500/0.2 ppm and SO2 0–10,000/0.2 ppm sensing) + optional #echem or #paramagnetic O2 0–25/0.1 or 0.2 % sensing



TVA2020 Toxic Vapor Analyzer #FID combined with #PID (linear range: FID 1–50,000 ppm CH4, PID 0.5–2,000 ppm isobutylene) for #Method21 compliance#LDAR




Ambient Particulate Monitoring

5014I Beta Continuous Ambient Particulate Monitor #BetaAttenuation (range: 0–1 to 10 mg/m3; LoD: 1–6 ug/m3; PM1, PM2.5, PM10 and TSP)

EPA approved equivalent monitor #EQPM1102-150 and #EQPM0609-183



5028I Continuous Particulate Monitor #BetaAttenuation (range: 0–0.1 to 10 mg/m3; LoD: 1–4 ug/m3; PM2.5 and PM10)

EPA approved equivalent monitor #EQPM1102-150 and #EQPM0609-183



TEOM1405, TEOM1405D, TEOM1405F and TEOM1405DF #TEOM Continuous Dichotomous Ambient Air Monitor (range: 0–1 g/m3; resolution: 0.1 ug/m3; PM1, PM2.5, PM10 and TSP) *F versions utilize #FDMS modules to measure the mass concentration of volatile and non-volatile components of PM

EPA approved equivalent monitor #EQPM-0609-182, #EQPM-1013-207, #EQPM-1013-208


1400AB Continuous Ambient Particulate TEOM™ Monitor (discontinued!)



















5030I SHARP Monitor #nephelometer combined with #BetaAttenuation (range: 0–1 to 10 mg/m3; LoD: 1-6 ug/m3; PM2.5 and PM10)

EPA approved equivalent monitor #EQPM-0609-184



5020i Sulfate Particulate Analyzer (range: 0–5 to 100 ug/m3; LoD: 0.5 ug/m3) thermally reduces SO4 to SO2, which is then measured by #fluorescence



PDR-1500 personal DataRAM™ Aerosol Monitor (PM size range: 0.1 to 10 um; with aerodynamic sizing)



Air Quality Monitor

GM-5000 Air Quality Monitor (#OPC PM sensor, #echem toxic gases CO/O3/NO/NO2/SO2, #PID total VOC detection)


ADR1500 Area Dust Monitor (#nephelometer PM1 to PM10 sensor)




Recent Posts

See All

Comments