top of page
Writer's pictureTeam Adsentec

Figaro Engineering Inc.

Updated: Feb 15, 2023

Location: Osaka, Japan

 

Products:

Gas sensors


TGS2600 (#MOx, high sensitivity to total air contaminants)



TGS2602 (#MOx, high sensitivity to VOCs, ammonia and H2S)



TGS2603 (#MOx, high sensitivity to amine and sulfur series odor (trimethylamine, methyl mercaptan, etc.))



TGS2610-C00 (#MOx, quick response to LP gas #LEL)



TGS2610-D00 (#MOx, selective response for LP gas with built-in filter #LEL)



TGS2611-C00 (#MOx, quick response to LP gas #LEL)



TGS2611-E00 (#MOx, selective response for methane with built-in filter)



TGS2612-D00 (#MOx, comparable response to % #LEL of methane and LP gas)



TGS2620 (#MOx, high sensitivity to organic solvent vapors)



TGS2630 (#MOx, high sensitivity to low-flammable refrigerant gases)



TGS3830 (#MOx, high sensitivity to refrigerant gases, quick response, low power consumption)



TGS3870 (#MOx, dual gas detection for both methane and CO)



TGS5042-A00 (#echem, high repeatability/selectivity to CO, sensitivity data bar code on each sensor; 0 – 10,000 ppm CO)



TGS5141-P00 (#echem, compact CO sensor, sensitivity data bar code on each sensor; 0 – 5,000 ppm CO)



TGS6810-D00 (#catalytic, combustible sensor, linear output over a wide detection range; 0 – 100 % #LEL)



TGS6812-D00 (#catalytic, combustible sensor, high accuracy up to high concentration range, 0 – 100 % #LEL)



KE-12 (#echem, galvanic cell type Maxell oxygen sensor, quick response, 0 – 100 % O2)




KE-25F3 (#echem, galvanic cell type Maxell oxygen sensor, long life for 5 years, threaded top, 0 – 100 % O2)



KE-25 (#echem, galvanic cell type Maxell oxygen sensor, long life for 5 years, hexagonal top, 0 – 100 % O2)



KE-50 (#echem, galvanic cell type Maxell oxygen sensor, long life for 10 years, 0 – 100 % O2)



KE-25LF (#echem, lead-free galvanic cell type Maxell oxygen sensor, long life for 5 years, hexagonal top, 0 – 30 % O2)



KE-25F3LF (#echem, lead-free galvanic cell type Maxell oxygen sensor, long life for 5 years, threaded top, 0 – 30 % O2)



SK-25 (#echem, galvanic cell type oxygen sensor, compact, 0 – 30 % O2)



TGS4260 (#echem, lead-free potentiostatic electrolysis-type oxygen sensor, compact, 0 – 25 % O2)



FECS40-1000 (#echem, high accuracy carbon monoxide sensor, 0 – 1000 ppm CO)



FECS41-250 (#echem, high sensitivity to nitric oxide, high accuracy, 0 – 300 ppm NO)



FECS42-20 (#echem, high sensitivity to nitrogen dioxide, high accuracy, 0 – 30 ppm NO2)



FECS43-20 (#echem, high sensitivity to sulfur dioxide, high accuracy, 0 – 20 ppm SO2)



FECS44-100 (#echem, high accuracy, Low ppm range < 100ppm ammonia sensor, 0 – 100 ppm NH3), FECS44-200 (#echem, high accuracy, Low ppm range < 200ppm ammonia sensor, 0 – 200 ppm NH3), FECS44-1000 (#echem, high accuracy, middle detection range up to 1000ppm ammonia sensor, 0 – 1000 ppm NH3), FECS44-5000 (#echem, high accuracy, wide detection range up to 5000ppm ammonia sensor, 0 – 5000 ppm NH3)



FECS45-10 (#echem, high sensitivity to chlorine, high accuracy, 0 – 10 ppm Cl2)



FECS50-100 (#echem, high sensitivity to hydrogen sulfide, high accuracy, 0 – 100 ppm H2S)



Gas Modules

CMM5042 (#echem CO sensor; range: 0 – 800 ppm; voltage output; for domestic safety, CO detectors, and appliance control)



CGM8612-B00 (#catalytic hydrogen, methane, butane and propane sensor, pre-calibrated for hydrogen detection; range: 0 – 14,000 ppm H2; analog voltage output; for industrial safety and fuel cell power system)



LPM2610-D09 (#MOx butane and propane sensor, pre-calibrated alarm set point for LP gas; alarm set point: 1250 ppm; for domestic safety and LP gas detector)



NGM2611-E13 (#MOx methane sensor, pre-calibrated alarm set point: 5000 ppm CH4; for domestic safety and LP gas detector)



FCM2630-C01 (#MOx refrigerant gas sensor, pre-calibrated alarm set point: 5000 ppm R-32; analog output; for refrigerant gas leak detection in air conditioning/refrigeration systems)



FCM2630-E00 (#MOx refrigerant gas sensor, pre-calibrated alarm set point: 5000 ppm R-32; digital output; for refrigerant gas leak detection in air conditioning/refrigeration systems)



Recent Posts

See All

Comentários


bottom of page